Python Scripting For Storage Admin - How To Read & Write In File.
Python Scripting How To Open Read & Write In File
In this videos we will see how we can open file using python script then we will write some content in the file and then save it using python script. This is also called as file handling in python script.
Below is the code which is explained in above video.
Below line will open a file for writing purpose. You can use "r" for read and "a" for append.
s=open("file.txt","w")
This line will write some content in the file. \n is the newline character which writes data in a new line.
s.write("this is a file2\n")
Below line will save the data and close the file. If you miss below line then data will not get saved.
s.close()
This line will read the entire content of file and store it in a variable read_file.
read_file=open("file.txt","r").read()
Below line will print the content which is stored in variable read_file.
print(read_file)
For more details and live demo please refer to the below video. Subscribe to youtube channel as well and stay tuned for more videos in this video series.
Why system admin Should Learn Python Scripting. In this video i have explained few reason to start learning scripting. You can learn any scripting language but choosing python will will give you many advantage as below.
Python Scripting for Storage Admin
1.What is scripting ?
It is a bunch of code written in any programming language which perform certain task in specific sequence.
2.Why Storage Admin Learn Scripting
To make your life easy. If you have lot of server or storage devices which support ssh and regularly login to those device to check health status and it killing your time then learn scripting and automate it. Also if you want to start career in DevOps then you must a scripting language.
3.Why Python
Its a very easy language and platform independent. Its a very powerful language which is widely being used in many popular website.
4.Popular Websites Which Uses Python
nasa.gov Google Search Engine InstaGram Quora
5.What Would be In this Series?
First Couple of video we will discuss about basic in python then we will start write a code which will login to the system remotely and execute some command to get some output.
Question And Answer For NS0 158 Netapp Certification Exam
Here are some sample question and answer for NS0 158 netapp certification exam. This is also called as NCDA Netapp Certified Data Administrator for cluster mode netapp data ontap 9.1. This are sample question and not the expected question for real exam.
Regarding storage failover giveback processes, which statement is true?
A. During giveback, node cl1-01 simultaneously returns ownership of both root and data aggregates
to cl1-02.
B. During giveback, node cl1-01 returns ownership of all aggregates to cl1-02, before reverting the
data LIFs back to the home ports.
C. During giveback, node cl1-01 returns ownership of the root aggregate to cl1-02 before returning
ownership of the data aggregates.
D. During giveback, node cl1-01 moves ownership of the root aggregate to cl1-04 and ownership of
the data aggregates to cl1-04.
Answer: C
Explanation:
The following process takes place in a normal giveback. In this discussion, node A has taken over
node B. Any issues on Node B have been resolved and it is ready to resume serving data.
References: https://library.netapp.com/ecmdocs/ECMP1196905/html/GUID-E8DC7475-49ED-4397-
9F00-AC5CB2875CA5.html
NO.2 A customer has a 1,000 GB volume used as a NAS share that has 3x 100 GB files and has no existing Snapshot copies.
The customer creates a Snapshot copy of the volume, adds a 500 Gb file to the volume, and then
deletes one of the 100 GB files from the volume. How much free space is in the volume in this scenario?
A. 500 GB
B. 200 GB
C. 300 GB
D. 600 GB
Answer: B
Explanation:
Snapshot copies minimize disk consumption by preserving individual blocks rather than whole files.
Snapshot copies begin to consume extra space only when files in the active file system are changed
or deleted. When this happens, the original file blocks are still preserved as part of one or more
Snapshot copies.
References: https://library.netapp.com/ecmdocs/ECMP1368826/html/GUID-CF9E77A6-BDD9-4138-
A281-FC0E7BEA4C6D.html
NO.3 Which NetApp management tool verifies the disk-shelf cabling of an existing NetApp cluster?
A. System Setup
B. Config Advisor
C. OnCommand Unified Manager
D. OnCommand System Manager
Answer: B
Explanation:
NetApp Config Advisor is a tool that will allow you to check the health and ensure your NetApp
infrastructure is adhering to NetApp best practices. Once the Config Advisor query finishes, view the results and take corrective action on any configuration issues:
References: http://bestpracticetips.com/tag/config-advisor/
NO.4 You are configuring an ONTAP solution for FC host connectivity.
In this scenario, how should the cluster be configured? (Choose two.)
A. The SVM must be configured for Ethernet LIFs.
B. FC ports must be configured as initiators.
C. FCP must be licensed on the cluster.
D. FC ports must be configured as targets.
Answer: CD
Explanation:
You can configure the FC and the FCoE protocols on the SVM for SAN hosts. LIFs are created on the most suitable adapters and assigned to port sets to ensure data path redundancy. Based on your requirements, you can configure either FC, FCoE, or both the protocols. Before you begin The FCP license must be enabled on the cluster. All the nodes in the cluster must be healthy. Each node must have at least two correctly configured ports for each protocol (FC and FCoE).
NO.5 You have a FlexVol volume with LUNs and need to set policies to prevent an ENOSPC error on the host. In this scenario, which two commands will keep the LUN available to the host? (Choose two.)
A. volume autosize
B. snapshot autodelete
C. snapshot delete
D. volume size
Answer: B,C
Explanation:
ENOSPC is a UNIX operating system error that sometimes returns the message Not enough space is
available to service your request." The error message occurs because of a shortage of file system
space or lack of available media blocks. You can delete Snapshot copies manually, or automatically by enabling the Snapshot autodelete capability for the volume. Define and enable a policy for automatically deleting Snapshot copies by using the volume snapshot autodelete modify command.
You can use the snap delete command to delete a Snapshot copy before the preset interval to free
disk space or because it is a manual Snapshot copy that is no longer needed but is not going to be
automatically deleted.
Note: We get ENOSPC errors because Data ONTAP lets the Snapshot copy grow into the volume
space. Every write in WAFL is a write to a new block. If an old block is part of a Snapshot copy, Data
ONTAP needs to preserve the old block and the new changed block. This is not a problem specific to NetApp. Every storage vendor who supports a snapshot feature has to deal with it. There are two options when there is no space to accommodate the Snapshot copies: References: https://community.netapp.com/fukiw75442/attachments/fukiw75442/backup-andrestore-
discussions/5980/1/tr-3633.pdf
NO.6 To log in to the cluster with OnCommand System Manager, a cluster administrator account must be authorized for which two application types? (Choose two.)
A. HTTP
B. SSH
C. ONTAPI
D. service processor
Answer: A,C
Explanation:
You must have a cluster user account configured with the admin role and the http, ontapi, and
console application types.
References: https://library.netapp.com/ecmdocs/ECMP1636037/html/GUID-0E8373DA-D297-4FBA-9C4D-3AD3C169D37F.html
NO.7 When a two-node cluster is expanded, which cluster configuration would be supported?
A. a 4-node switched cluster
B. a 4-node switchless cluster
C. a 3-node switched cluster
D. a 3-node switchless cluster
Answer: A
Explanation:
If you are adding nodes to a two-node switchless cluster, you must have installed and configured the
cluster management and interconnect switches before adding additional nodes.The switchless cluster functionality is supported only in a two-node cluster.
References: https://library.netapp.com/ecmdocs/ECMP1636037/html/GUID-B13FF812-785E-4E62-
9914-30E7A8F51A4C.html
What Is And How To Create Flexclone Volume In NetApp Cluster
In this video we will see how we can create flexclone volume in netapp cluster mode. We have used flexclone volume CLI command to create flexclone.
Flexclone volume is also called as flexible clone. Flex clone are the point in time copy of an source volume which can be use for testing purpose. After flexclone creation what ever changes happen in any of the volume it does not effect each other data.
Flexclone Share the same space of it source volume means it will not consume any extra space from its container aggregate. If you want flexclone to be a separate volume then flexclone split operation can be done.
How To Create iSCSI LUN And Discover In Windows Host Netapp Cluster Mode
Today we will discuss how we can create iscsi LUN in SVM NetApp Cluster Mode and allocate it to a Windows Host. In previous video we discussed how to configure iSCSI in SVM Netapp Cluster Mode. Click here to know more about it. Below are the overall steps need to perform in order to create iSCSI LUN in SVM NetApp Cluster Mode and how we can allocate it to windows host.
How To Create iSCSI LUN And Discover In Windows Host Netapp Cluster Mode
Complete Steps to Create iSCSi LUN in SVM NetApp Cluster Mode
1. Create Volume in SVM
2. Create a LUN over the volume
3. Create PortSet in SVM
4. Create a Initiator group in SVM
5. Bind the Igroup in portset
6. Map the LUN to Igroup
7. Discover the device in Windows Server
We are going to discuss about each step one by one along with the command that we need to use to enable Create iscsi LUN in SVM NetApp Cluster Mode.
Step 1: Create Volume in SVM Netapp Cluster Mode
Below command will create a volume in SVM NetApp Cluster Mode. This step is necessary because a LUN can reside over a volume or qtree. The volume should be thick volume as per netapp best practice recommendation.
Step 2. Create a LUN over the volume in SVM Netapp Cluster Mode
In this step we will create a LUN over a volume. As per netapp best practice recommendation we should create a thick volume. In this command the “-space-reserve enable” makes the LUN as thick.
If your host operating system is Windows 2012, you must use the windows_2008 ostype. Space-reserve is enabled by default. If you want a non-space-reserved LUN, you must set the space-reserve option to disabled.
Step 3. Create PortSet in SVM Netapp Cluster Mode
Port Set are nothing but grouping of target iSCSI lifs. It is better to use ports sets when we have multiple targets on a node and you want to restrict access of a certain target to a specific initiator. Do not confuse port set with the physical ports.
Below is the command which will create a port set and add two iSCSI target lif.
You can see the port set details by executing the below command.
portset show -vserver vs1
Step 4. Create an Initiator group in SVM Netapp Cluster Mode
In this step we are going to create initiator group in SVM. This is also called igroup which is nothing but collection of initiator IQN number. In iSCSI lun allocation IQN are similar to WWPN in FC protocol.
Step 5. Bind the Igroup to portset in SVM Netapp Cluster Mode
In this step we will bind the igroup to the portset. Once this step is completed the the initiator will be able to communicate to the iSCSI target lif which are present in port set. Below is the command to bind an igroup to portset in SVM.
Steps 6: Map iSCSI LUN to Igroup In SVM Netapp Cluster Mode
In this step we will map or present the lun to the igroup1 and then the lun will be visible to initiator. Below is the command to map the iscsi lun to an initiator.
LUNs on your Storage Virtual Machine (SVM) appear as local disks to the Windows host. You must manually rescan disks to discover the new LUN. Below are the steps to do it for windows 2008 server
Steps 1. Open the Windows Computer Management utility:
Navigate to Computer Management Windows Server 2008 Start > Administrative Tools > Computer Management
2. Expand the Storage node in the navigation tree.
3. Click Disk Management
LUNs appear in Windows Disk Management as disks. You need to initialize the disk as a basic disk with a GPT or MBR partition table to create a drive. You need to format the LUN with a file system such as NTFS, below are the steps to do it.
Steps 1. Start Windows Disk Management.
Steps 2. Right-click the LUN, and then select the required disk or partition type.
Steps 3. Follow the instructions in the wizard.
Once these steps are completed you can go to My Computer and can see new drive. Make sure that you create and delete files in the drive. This concludes the steps on iscsi lun creation in SVM and present it to a windows server. Below is a Youtube video which explains more on each steps and commands. You can also like and subscribe to You Tube channel for more such videos.
How To Configure iSCSI In SVM And Windows Server Netapp Cluster Mode
Today we will discuss how we can configure iscsi in SVM NetApp Cluster Mode. Basically iSCSI protocol is used for LUN allocation to various host. In iSCSI the data transfer happens via network. This is why the performance is less in comparison to the FC protocol. You can try increase the performance by using 10G network port and by enabling Jumbo Frames. Below are the overall steps need to perform in order to configure iSCSI in SVM NetApp Cluster Mode.
Complete Steps to configure iscsi in SVM NetApp Cluster Mode.
1. Add iSCSI License is Netapp Custer
2. Add iSCSI protocol in SVM allowed Protocol List
3. Create iSCSI Server in SVM Netapp
4. Create iSCSI Lif in each node of the cluster
5. Discover iSCSI target in windows server
We are going to discuss about each step one by one along with the command that we need to use to enable iSCSI in SVM NetApp cluster mode.
Step 1: Add iSCSI License is Netapp Custer Mode
Below command will add the iSCSI licence in NetApp cluster mode.
cluster1::> system license add -license-code AAAAAAAAAAAAAAAAAAAAAAAAAAAA
Once the command is executed you can execute the below command to see if iSCSI licence added or not ?
cluster1::> system license show
Step 2: Add iSCSI Protocol in SVM allowed protocol list
Before we use any Protocol in SVM we need to check whether that particular protocol is present in the protocol list of SVM or not. Below command will show what are the protocol present in SVM.
cluster1::> vserver show-protocols -vserver vs1
If you see iSCSI in the output of above command then we can proceed for the next step. Else we need to add the iSCSI protocol in the SVM by using the below command
Step 3: Create iSCSI server in SVM Netapp Cluster Mode
In this step we are going to enable iSCSI Protocol in SVM once we done with this step then only we will be able to perform iSCSI operations in SVM.
cluster::> vserver iscsi create -vserver vs1
In order to verify if iSCSI service is enabled or not you can execute the below command
cluster::> iSCSI show -vserver vs1
Step 4 Create iSCSI LIF In SVM Netapp Cluster Mode
In this step we will create iSCSI lif. iSCSI lif creation is similar to normal lif creation only difference is that we have to mention iscsi protocol while creating the lif. In order to maintain the multipath we must create lif in each node of the cluster. Below is the command to create lif on node 1.
Now all the steps from Netapp side is completed. Now follow the below steps to complete the configuration from Windows Side.
Steps 5: Discover iSCSI target in windows server
1. Open the iSCSI Initiator Properties dialog box:
Windows Server 2012 Server Manager > Dashboard > Tools > iSCSI Initiator
Windows Server 2008 Start > Administrative Tools > iSCSI Initiator
2. On the Discovery tab, click Discover Portal or Add Portal, and then enter the IP address of the
iSCSI target port.
3. On the Targets tab, select the target you discovered, and then click Log on or Connect.
4. Select Enable multi-path, select Automatically restore this connection when the computer
starts or Add this connection to the list of Favorite Targets, and then click Advanced.
5. For Local adapter, select Microsoft iSCSI Initiator.
The following example is from Windows Server 2008:
iSCSI Configuration In Windows Netapp Cluster Mode
6. For Source IP or Initiator IP, select the IP address of a port on the same subnet or VLAN as one
of the iSCSI target LIFs.
7. Retain the default values for the remaining check boxes, and then click OK.
Once the steps from Windows side is done. We will be able to see the iSCSI initiator in SVM as well. Below is the command to see them.
cluster::> iSCSI initiator show -vserver vs1
Now the SVM is ready to server iSCSI traffic. Next step is to create a lun and map it to the windows server. In windows server the lun will be mapped as local drive and can be used for data operation. Check Out the YouTube Video which explains each steps in details along with the command line Demo. Subscribe to our YouTube Channel as well.
This video explains all possible things that you should know about inode in Netapp Cluster Mode.
Detail Explanation Of Inode Netapp Cluster Mode
What is Inode In Netapp Cluster Mode ?
An inode is a data structure or object which contain information about files in Netapp Cluster Mode. An inode is a data structure that defines a file, with an exception of filename which is stored in the directory entry. The inode number is an integer unique to the volume. Whenever a user create a new file an inode is assigned to contain all the information about the file.
What is the Size of One Inode In Netapp Cluster Mode ?
The size of a inode depends upon model to model. Based on the model and the block size of the volume we can say what would be the size of one inode in NetApp cluster mode. If a netapp volume has block size of 4 KB then the one inode will consume 4 KB of space and if the block size of volume is 32 KB then it will consume 32 KB of space.
Command to check block size of volume in netapp cluster mode.
In order to get the block size of netapp volume we need to run node level command. Below command output will give you the block size of all volume which belongs to node 01.
run -node Cluster-01 -command vol status -b
How To Calculate Maximum Inode Of Volume In Netapp Cluster Mode ?
The simple formula is total capacity of volume in KB divided by block size of the netapp. Below is an example where the total volume size is 20 MB or 20480 KB and the block size is 4 KB.
Formula For Calculating Maximum Inode Of Volume In Netapp Cluster Mode
Total Approx Inode = Total Size Of the Volume in KB/Block Size of the Volume
Total Approx Inode = 20480/4 = 5120
5120 is approximate value for maximum inode. If you want to know the exact value then select a value which is much higher than 5120 and try to increase the Inode. The Ontap will give you error and it will also have the exact value of inode that a volume can have.
How to Check Total Number Of Inode of Volume In Netapp Cluster Mode ?
We can check the total number of inode of volume in NetApp cluster mode by using two commands.
Command To Check Number Of Inode Of Volume In Netapp Cluster Mode
df -h vol1
Output of above command will show the total number of free inode and the used inode of a volume and the sum of those will give you the total number currently allocated inode for the volume. You can also use the below SVM level command to get total number currently allocated inode.
Command To Check Number Of Inode Of Volume In SVM Netapp Cluster Mode
vol show -vserver vs1 -volume vol1 -fields files
Output of above command will give the total number files that can be created in a volume which is also is the inode of the volume.
How To Increase Inode Of Volume In Netapp Cluster Mode ?
We need to increase the number of file of volume to increase the inode. As per Netapp best practice recommendation inode should be increased by 2%.
Command to Increase Inode Of Volume In Netapp Cluster Mode.
vol modify -volume vol1 -files 2000
If the value is larger than the maximum inode capacity the ontap will throw an error. This concludes the blog on Inode. Below is an YouTube Video to see the demo on how to perform all steps to increase the inode in Netapp Cluster Mode.